OCWD Management Area
Figure 1-6: Example Hydrographs
Each year OCWD calculates the volume of groundwater storage change from a theoretical “full” benchmark condition based on a calculation using changes in groundwater elevations in each of the three major aquifer systems and aquifer storage properties. This calculation is checked against an annual water budget that accounts for all production, measured recharge and estimated unmeasured recharge (also referred to as “incidental recharge”) . The amount of available or unfilled storage from the theoretical full condition is shown on Figure 1-3. Maintaining the basin storage condition on a long-term basis within the established operating range allows for long-term sustainable management of the basin without experiencing undesirable effects. Therefore, the undesirable result of “significant and unreasonable r eduction of groundwater storage” is not present and is not anticipated to occur in the OCWD Management Area in the future due to OCWD’s management programs .
BASIN 8-1 ALTERNATIVE 2022 UPDATE
Executive Summary 1-11
Appendix F - 77